Please note that this site is unsupported on Internet Explorer, and may not function as intended.

We recommend upgrading to the latest version of Microsoft Edge, Google Chrome or Firefox.

Test & Collection Guide

 New search...

Keyword Search:

Test name:

  

Manual search:

Holotranscobalamin

Ordering information:

Holotranscobalamin will be automatically added if serum Total B12 is <270 pmol/L. If the serum Total B12 is >270 pmol/L,Holotranscobalamin will not be done.

 

Alternate names:
Active B12
Laboratory:
Biochemistry
Test Code:
HOLOTC
Specimen types:
Serum
Container types:
Serum tube with gelSerum tube with gel
Collection Instructions:
Transport specimen at Room Temperature to lab

Please note that heparinised plasma IS NOT SUITABLE for this test.  The only sample type which can be used is serum.

Minimum Adult Volume:
1 mL
Frequency:
Daily
Result Turnaround Time:
2 hours
Reference Interval:

38-188 pmol/L

Pathology Handbook

Test & Collection Guide

Feedback

Eastern Health Pathology always welcomes the opportunity to improve the service we provide you.